PI generator torque controller in region 1 (variable speed, variable power), starting at istate = 3 K = 0.108313E+07 [Nm/(rad/s)^2] PI generator torque controller in region 2 (constant speed, variable power) I = 0.307683E+08 [kg*m^2] Kp = 0.135326E+08 [Nm/(rad/s)] Ki = 0.303671E+07 [Nm/rad] PI pitch angle controller in region 3 (constant speed, constant power) Kp = 0.249619E+01 [rad/(rad/s)] Ki = 0.120122E+01 [rad/rad] K1 = 7.30949 [deg], K2 = 1422.81187 [deg^2] (dq/dtheta = -176.48944 kNm/deg) Additional terms due to the Aerodynamic damping Kp2 = 0.240394E-01 [rad/(rad/s)] Ko1 = -1.69769 [deg], Ko2 = -15.02688 [deg^2] (dq/domega = 243.08924 kNm/(rad/s))